Mc-41103400
For sale
Kansas » Kansas » China
520
USD
AMIKON LIMITED
Sales Manager:Nancy
Email:info@amikon.cn
Wechat + 8618020776786
Skype:onlywnn_1
Website: www.amikon.cn
Advantage Brands:
Allen Bradley: Reliance,SLC500/1747/1746,Logix5000/1756,PLC-5/1771/1785
ABB: DSQC series,H&B Freelance,Bailey
Bently Nevada: 3500 System spare parts ,3300 System spare parts
Yokogawa DCS
Honeywell DCS
Ovation: 1C31234G01/1C31227G01/1C31166G01/1C31116G01/1C31189G01 etc DCS System spare
GE: IC693/IC697/IS200/DS200/IS215
Triconex: 3700A/3805E/3604E/3503E/3504E/3008/4119A/8312/3703E/3511/
Schneider 140 PLC series 140CPU67160/140CRP93200/140CPS11420
AMIKON LIMITED to the "professional, integrity, innovation, cooperation, win-win"
business philosophy, and constantly develop new products, to provide quality services, in order
to maximize the pursuit of customer satisfaction, and constantly open up new areas of business for customers.
MC-4/11/03/400
MC-4/11/03/400
MC-4/11/03/400
The height of the graphical display area is 300 pixels, and it is divided
into six parts by broken lines. By scaling the actual values to be
monitored, the display curves can be placed inside the area in the Y
direction.
The width of the area is 500 pixels and it is divided into 10 parts by
broken lines. If the updating interval of the actual values to be monitored
is e.g. 5 ms (the fastest possible), then the width of the entire area
corresponds to a time of 2.5 seconds (500 * 5 ms).
A curve can display either a normal value or a bit value. If you want to
display an normal value then you can define the scalings and offsets to
be used in the display by clicking the Scaling Def push button in the
Channel dialog box.
If you want to display a bit value then you must define the bit number
(0...15) to be displayed. The scaling and offsets of the bit display are
fixed.
Real-time graphical display starts automatically when you set the graph
display mode to normal or bit in a channel and click the OK button. At
the left sides of the push buttons, corresponding to the channels
selected, there will be a square mark (if you click on this mark you can
see the physical scaling and physical on-line value of the channel).
The display can be stopped by using the F4 function key. Now the
vertical broken lines and time values of the graduations on the X axis
will be shown. You can continue the display operation by pressing the
F4 function key again.
You can, if needed, remove the stopped graphical display from the
screen by selecting the command Clear Graph Area in the menu.
KLASCHKA Typ: SAG/B-p34r Sach-Nr. 131406
Omron E3X-DA41-S
elap s.r.l E320 Type: E320200824PP
ifm AC007S Sicheres
Schmalz SGM 20 G1/8-AG 1,5 - 6bar Riegler KOM 8073/5
Pepperl+Fuchs LFL2-CK-U-PVC3 No. 041646
Siemens QAE3010.016 Pt100
Ipf Electronic LS030102 L.
Balluff BGL000C BGL 120A-005-S49 10 - 30V DC
Sick WTB9M4L-3P2461 1058187 10 - 30V
Balluff BOS 26K PA-1LQK-S4-C 111718
SUNX VF-RM5-3 B2
SICK WT24-B2101 1011419
Siemens TH100 7NG3211-0NN00 HW01.00 FW01.01.00
Pepperl + Fuchs NJ15-30GM50-E2 No. 16078S
Pepperl+Fuchs NJ50-FP-A2-P1 No. 027684
Wenglor sensoric UF87PA3
Ashcroft CX40F0142100PA 100 Pa 12-36Vdc
Graeff 7043 1xFe-CuNi/J
Ifm efector100 KI0040 KI-2015-FBOA/SS-000-K
Ifm Efector IB-2030-ABOA
PEPPERL + FUCHS NJ15-30GK-N Part. Nr. 08685
Sick Lichttaster VT180-S142 Nr. 6008933
Leuze LVS 420/P 50027192
Keyence LV-21AP
Keyence LV-22P
Murr Elektronik MVH6S-RNB10.0
Omron E3Z-LR86 E3ZLR86
SICK WL18-2P430 102908
Turck Ni20U-G30-ADZ30X2-B3131 Id. No. 4281813
Visolux RLK6/7c/16/40a/53 9.417073
Sensopart FR 20 R-PSM4 553-11000
Sensopart FT 20 RH-NSM4 Art: 551-11002
DATALOGIC ET3-1781 Photo-Sensor 3M4038
Schmersal BNS260STG-AS-L BNS 260 STG-AS-L
SUNX VF-RM5-3 UVFRM53 3FEK 0104-2501-00
Balluff Induktiver Sensor BES 516-114-SA1-05
ifm efector500 PY5022
Rotech PCR3MVAZ PB-Modul Crouzet 83.161.301W2
Balluff BNS 113-04-R12-100 12-04
Keyence LV-H32 Laser Sensor-Kopf
Endress+Hauser NIVOCOMPACT FTC 730
Schmersal BNS260STW-AS-L 101186158
KEYENCE FU-16Z