Abb 424k1105
For sale
Kentucky, Louisville, xiamen
$
520.00
USD
AMIKON LIMITED
Sales ManagerNancy
Emailinfo@amikon.cn
Whatsapp/Skype + 8618020776786
Website www.amikon.cn
Advantage Brands
Allen Bradley Reliance,SLC500/1747/1746,Logix5000/1756,PLC-5/1771/1785
ABB DSQC series,H&B Freelance,Bailey
Bently Nevada 3500 System spare parts ,3300 System spare parts
Yokogawa DCS
Honeywell DCS
Ovation 1C31234G01/1C31227G01/1C31166G01/1C31116G01/1C31189G01 etc DCS System spare
GE IC693/IC697/IS200/DS200/IS215
Triconex 3700A/3805E/3604E/3503E/3504E/3008/4119A/8312/3703E/3511/
Schneider 140 PLC series 140CPU67160/140CRP93200/140CPS11420
AMIKON LIMITED to the professional, integrity, innovation, cooperation, win-win
business philosophy, and constantly develop new products, to provide quality services, in order
to maximize the pursuit of customer satisfaction, and constantly open up new areas of business for customers.
Check that the Prevention of Unexpected Start function (if installed)
works
ï Start and Stop the drive and wait until the motor has stopped.
ï Open the Prevention of Unexpected Start switch (mounted on a control
desk).
ï Give a Start command. The drive should not start.
ï Reset the drive.
Optional function. See delivery
specific circuit diagrams.
Check that the cooling fans rotate freely in the right direction, and the air
flows upwards.
Check visually that the fans rotate in
the direction indicated by an arrow
on the fan housing.
Check the direction of rotation of the motor.
Check the correct operation of the emergency-stop circuits from each
operating location.
If the unit is equipped with an air circuit breaker, check the current trip
limits of the breaker (preset at the factory).
General rule
Ensure the selectivity condition is fulfilled i.e. the breaker trips at a lower
current than the protection device of the supplying network, and that the
limit is high enough not to cause unnecessary trips during the
intermediate DC circuit load peak at start.
Long-term current limit
As a rule of thumb, this should be set to the rated AC current of the
module.
Peak current limit
As a rule of thumb, this should be set to a value 3-4 times the rated AC
current of the module.
Optional device. See the delivery
specific circuit diagrams.
Check the settings of the relays and breakers/switches of the auxiliary
circuits.
Optional devices. See delivery
specific circuit diagrams.
Disconnect any unfinished or unchecked 230/115 VAC cables that lead
from the terminal blocks to the outside of the equipment.
Locate the PPCS branching unit (APBU-xx). Enable memory backup
battery by setting actuator 6 of switch S3 to ON
PN 740-33050-AD/E
115UMD300CBCAA
M225-060-XL
332U34201
8045R2-1-ES-ASYST
D1369-26C
Materials 4000430
332U34035
100SCCM
MKS 113B-2
20951 P6000 W/DV-MAC
322U11978
GLC2300-TC41-24V
332U34025
332U33271
322U12302(Y1)
332U34037
FMH2A06TR-EN23Z
300SCCM
Neat 330UP
PN 335815-001 NEW
Materials 4000431
NEG PUMP CONTROLLER V1.1
UNISORB FIXATOR ANCHORING ALIGNMENT SYSTEM RKI
PCB 859-8369-008
MS8604A
UNI-1401
SGDA-01AS
Elmer 851-8220-011G
TAS-MAIN
Views: 69